BS EN 1990: basis of structural design and the UK National Annex

The Eurocode every other Eurocode rests on. Limit states, the partial factors, the combination factors and the design working life a UK building is designed for, as the UK National Annex sets them.

How we work

What is BS EN 1990?

BS EN 1990 is the Eurocode for the basis of structural design: the limit states a structure is checked against, how actions are combined and the partial factors applied to them. In the UK its National Annex sets the factors, 1.35 and 1.50 on permanent and variable actions for the STR check under Expression 6.10, the combination factors psi, and a 50-year design working life for buildings. Every other Eurocode depends on it.

  • Limit states EQU, STR and GEO
  • UK factors from Tables NA.A1.2(A) to (C)
  • Combination factors from Table NA.A1.1
  • 50-year design working life for buildings

What BS EN 1990 does

BS EN 1990, Eurocode: Basis of structural design, sets out the principles the whole suite shares: the limit states a structure is verified against, how actions are combined, the partial factors that turn characteristic values into design values, and the reliability the design is meant to achieve. Every material Eurocode assumes it, and every loading Eurocode feeds it. A calculation that cites BS EN 1993 for a beam has already used BS EN 1990 for the loads on it, whether or not it says so.

The ultimate limit states are separated by what is being checked. EQU is loss of static equilibrium of the structure or a part of it as a rigid body, overturning or uplift. STR is failure or excessive deformation of the structure or its members. GEO is failure of the ground. Each has its own set of partial factors in the UK National Annex, and using the STR set where EQU governs, or the reverse, is one of the commoner errors in a package we are asked to check.

The UK partial factors

The UK National Annex to BS EN 1990:2002 gives the factors in its Tables NA.A1.2(A), (B) and (C). For EQU, permanent actions are factored at 1.10 where unfavourable and 0.90 where favourable, with the leading variable action at 1.50. For STR and GEO under Expression 6.10, permanent actions are factored at 1.35 unfavourable and 1.00 favourable, variable actions at 1.50. Set C, used with Design Approach 1 for geotechnical verification, is 1.00, 1.00 and 1.30.

The National Annex also permits the pair of Expressions 6.10a and 6.10b in place of 6.10 for the STR check of buildings. In 6.10b the permanent action factor is reduced by the factor xi of 0.925, giving 1.25 on unfavourable permanent actions with the full 1.50 on the leading variable action. For most building structures 6.10b governs and is less onerous than 6.10, which is why a package should say which expression it used; two engineers can both be right and disagree by a few percent on the same member.

The UK adopts Design Approach 1 for geotechnical design, at clause NA.2.2.4, which is why BS EN 1997 packages in the UK run two combinations rather than one.

Combination factors and design working life

The combination factors psi0, psi1 and psi2 in Table NA.A1.1 reduce accompanying variable actions to the values likely to coincide with the leading one. For imposed loads in Category A domestic and residential areas they are 0.7, 0.5 and 0.3. For wind they are 0.5, 0.2 and 0. For snow at sites at or below 1000 m they are 0.5, 0.2 and 0. For roofs in Category H, roofs not accessible except for normal maintenance and repair, they are 0.7, 0 and 0, so a maintenance load never appears in a quasi-permanent combination.

Table NA.2.1 gives the indicative design working lives. Buildings and other common structures are Category 4, 50 years. Temporary structures are Category 1, 10 years. Replaceable structural parts, such as gantry girders and bearings, are Category 2, 10 to 30 years. Agricultural and similar structures are Category 3, 15 to 25 years, and monumental buildings, bridges and other civil engineering structures are Category 5, 120 years. The category matters beyond durability: it is what a seasonal wind or snow factor is allowed to rest on for a temporary structure.

Where it goes wrong

Using the EQU factors for a member check or the STR factors for an overturning check. Mixing 6.10 and 6.10b within one package without saying so. Taking the Eurocode's recommended values instead of the National Annex's, which are not always the same. Omitting psi factors so that every variable action appears at full value at once, which over-designs the structure and, worse, hides the governing case. And for temporary and event structures, failing to state the design working life that the reduced wind and snow values depend on.

A package prepared to BS EN 1990 states the limit states checked, the expression used, the factors applied with their table references, and the design working life. That is what lets a checker reproduce it, and it is how our calculation packages and our independent checks are set out. The wider suite is described on the Eurocodes hub.

Documents cited

  • BS EN 1990:2002, Eurocode: Basis of structural design.
  • NA to BS EN 1990:2002, UK National Annex for Eurocode: Basis of structural design, Tables NA.A1.1, NA.A1.2(A), (B) and (C), Table NA.2.1 and clause NA.2.2.4.

Last reviewed 2026-11-08. Each citation above was checked against the document and edition named. This page describes the standards; it is not a design, and it does not replace a calculation prepared for a specific structure.

Questions

Common questions

What partial factors does the UK use for loads?

For STR and GEO under Expression 6.10, 1.35 on unfavourable permanent actions, 1.00 on favourable, and 1.50 on variable actions. For EQU, 1.10, 0.90 and 1.50. Under Expression 6.10b the permanent factor becomes 1.25. All from the UK National Annex to BS EN 1990, Tables NA.A1.2(A) and (B).

What is the design working life of a building?

50 years, Category 4 in Table NA.2.1 of the UK National Annex to BS EN 1990. Temporary structures are Category 1 at 10 years; bridges and monumental buildings Category 5 at 120 years.

What are psi factors?

Combination factors that reduce the accompanying variable actions to the values likely to act at the same time as the leading one. For wind in the UK they are 0.5, 0.2 and 0 for psi0, psi1 and psi2; for Category A imposed loads 0.7, 0.5 and 0.3.

Can I use Expression 6.10b instead of 6.10?

In the UK, yes, for the STR check of buildings: the National Annex permits the pair 6.10a and 6.10b. The package must say which it used, because the two do not give the same answer.