BS EN 1993-1-1: design of steel structures and the UK National Annex

Eurocode 3 replaced BS 5950 for the design of steel buildings. The UK National Annex sets the partial factors, and the standard's treatment of imperfections, global analysis and member buckling is where a package prepared by habit from the old code most often goes astray.

How we work

What is BS EN 1993-1-1?

BS EN 1993-1-1 is Eurocode 3, the standard for the design of steel structures, used in the UK with its National Annex. The National Annex sets the partial factors at 1.00 for cross-sections and member buckling and 1.10 for tension fracture. The standard links the global analysis to the member checks explicitly, assigns buckling curves by section type, and hands cold-formed purlins and rails to Part 1-3. It replaced BS 5950, withdrawn in 2010.

  • UK partial factors from NA.2.15
  • Buckling curves and imperfection factors from Tables 6.1 and 6.2
  • Member checks linked to the analysis route by 5.2.2(7)
  • Cold-formed members to BS EN 1993-1-3

Scope and status

BS EN 1993-1-1, Eurocode 3 Part 1-1: Design of steel structures, General rules and rules for buildings, is the core of steel design in the UK, used with its National Annex. Connections are in Part 1-8, cold-formed members and sheeting in Part 1-3, plated elements in Part 1-5 and fire in Part 1-2. It replaced BS 5950, withdrawn in 2010, which remains the document to read when appraising a steel frame designed before then.

The current edition in the library we work from is BS EN 1993-1-1:2005 with its UK National Annex. As with every part, the package names the edition and amendment applied.

The UK partial factors and material strengths

Clause NA.2.15 of the UK National Annex gives the partial factors for buildings: gamma M0 of 1.00 for the resistance of cross-sections, gamma M1 of 1.00 for the resistance of members to instability, and gamma M2 of 1.10 for the resistance of cross-sections in tension to fracture. The Eurocode's recommended gamma M2 is 1.25, so a net-section check that has used the recommended value rather than the UK one is conservative; the reverse error, using 1.10 under a National Annex that does not permit it, is the one to watch when a UK package is reused abroad.

Table 3.1 gives the nominal yield and ultimate strengths by product standard and thickness. For S235 to EN 10025-2 at thicknesses up to 40 mm the yield strength is 235 N/mm2 and the ultimate strength 360 N/mm2, with S275 and S355 following the same pattern at their own grades and the strengths stepping down above 40 mm. Taking a nominal grade strength without the thickness step is a routine error on heavy sections.

Global analysis, imperfections and member checks

Eurocode 3 makes an explicit link between the analysis and the member verification that BS 5950 left implicit. Clause 5.2.2(7)(a) states that no individual stability check to clause 6.3 is needed where second-order effects in members and the relevant member imperfections of clause 5.3.4 are totally accounted for in the global analysis. Otherwise, under 5.2.2(7)(b), the effects not included in the analysis are checked to clause 6.3 using the end moments and forces from it, and the buckling length may be taken as the system length.

In practice most building frames are analysed first order with amplification or second order without member imperfections, so the clause 6.3 member checks are still required, and the package should say which route it took. A frame analysed with a second-order, imperfection-including model and then also checked member by member to 6.3 has been designed twice; a frame analysed first order and never checked to 6.3 has not been designed at all.

Buckling curves and imperfection factors

Member buckling is handled through a reduction factor chi, found from the non-dimensional slenderness and an imperfection factor alpha that depends on the buckling curve. Table 6.1 gives alpha as 0.13, 0.21, 0.34, 0.49 and 0.76 for curves a0, a, b, c and d, and clause 6.3.1.2(4) allows buckling to be ignored where the slenderness does not exceed 0.2 or the ratio of design force to elastic critical force does not exceed 0.04.

Table 6.2 assigns the curve by section type and axis. For grades S235 to S420, hot-finished hollow sections take curve a and cold-formed hollow sections curve c; channels, tees and solid sections take curve c; and angles take curve b. The rolled I and H sections depend on their depth to breadth ratio and flange thickness. Choosing the curve for a cold-formed hollow section as if it were hot finished overstates its compression resistance materially, and is a finding we make in checking.

Cold-formed sections

Purlins, side rails, light gauge framing and most of the secondary steelwork on an industrial roof are cold formed, and they are designed to BS EN 1993-1-3, not Part 1-1. Clause 5.5.1 requires local and distortional buckling to be taken into account in determining both resistance and stiffness, with local buckling handled by effective widths to BS EN 1993-1-5 and the basic yield strength. Part 1-3 states its own recommended partial factors, gamma M0 and gamma M1 at 1.00 and gamma M2 at 1.25, which must be checked against the UK National Annex to Part 1-3 before they are cited.

On an existing industrial roof this is the part that governs purlin and rafter capacity under new plant or oversheeting, and the one for which manufacturers' load tables are most often used without the restraint conditions they assume. Our roof loading appraisals state the restraint assumed and the clause the capacity came from. Steel connections are to BS EN 1993-1-8, covered in the wider Eurocodes hub.

Documents cited

  • BS EN 1993-1-1:2005, Eurocode 3: Design of steel structures, Part 1-1: General rules and rules for buildings, Table 3.1, clauses 5.2.2(7) and 5.3.4, clause 6.3.1.2, Tables 6.1 and 6.2 and Annex B Table B.1.
  • NA to BS EN 1993-1-1:2005, UK National Annex to Eurocode 3, Part 1-1, clause NA.2.15.
  • BS EN 1993-1-3:2006, Eurocode 3, Part 1-3: Supplementary rules for cold-formed members and sheeting, clause 2(3)P and clause 5.5.1.

Last reviewed 2026-11-08. Each citation above was checked against the document and edition named. This page describes the standards; it is not a design, and it does not replace a calculation prepared for a specific structure.

Questions

Common questions

What partial factors does the UK use for steel?

gamma M0 of 1.00 for cross-section resistance, gamma M1 of 1.00 for member instability and gamma M2 of 1.10 for tension fracture, from clause NA.2.15 of the UK National Annex to BS EN 1993-1-1.

Is a member buckling check always required?

Not where second-order effects and the member imperfections of clause 5.3.4 are fully included in the global analysis, under clause 5.2.2(7)(a). Where they are not, clause 6.3 member checks are required using the forces and moments from the analysis.

Which buckling curve applies to a cold-formed hollow section?

Curve c, under Table 6.2, against curve a for a hot-finished hollow section of the same grade. The imperfection factors are 0.49 and 0.21 respectively.

Are purlins designed to BS EN 1993-1-1?

Cold-formed purlins and side rails are designed to BS EN 1993-1-3, which requires local and distortional buckling to be accounted for and refers to BS EN 1993-1-5 for effective widths. Part 1-1 governs the hot-rolled frame they sit on.