Steel column and post design by Lead Group
Home / Structural Design & Elements / Steel Column & Post

Steel column and post design

A column takes the load a beam collects and carries it vertically down to a foundation. We design steel columns and posts to the Eurocodes, checking buckling, base plates and connections, for clients across the UK.

How we work

When do I need a steel column instead of a wall?

When a beam or floor load needs to come down at a point rather than along a line, for example at the end of a beam in an open-plan space where there is no wall to carry it. We design the column to take that load safely to the foundation.

In detail

Compression, slenderness and buckling

A column is a compression member, and the way a compression member fails is different from a beam. A short, stocky post fails by the steel squashing when the load reaches the section's squash resistance. A slender column fails long before that, by buckling sideways, bowing out under a load well below the material's strength. The dividing line is slenderness, the effective length divided by the radius of gyration, and it is the single most important number in column design. We calculate the buckling resistance to BS EN 1993-1-1 using the appropriate buckling curve for the section, so the design reflects how the column will actually fail.

Effective length is where judgement matters. A column pinned top and bottom has an effective length equal to its actual length; one fixed at the base and free at the top, a flagpole condition, has an effective length of twice its height and buckles at a quarter of the load. Real supports sit between these cases, so we assess the restraint at each end honestly rather than assuming a favourable condition. Universal columns are the usual choice because their square-ish shape resists buckling about both axes similarly, but square and circular hollow sections are often chosen where the post is exposed and both appearance and efficiency matter.

Combined loading and base plates

Many columns do not carry pure axial load. A beam framing into the side of a column applies its reaction with an eccentricity, which adds a bending moment, and a column in a frame carries moment from the frame action as well. We check these members for combined axial and bending to the Eurocode interaction rules, because a column that passes on axial load alone can fail once the bending from an eccentric beam connection is included. Getting the connection eccentricity right is part of the design, not an afterthought.

At the bottom the column load has to spread out onto the foundation through a base plate. The base plate is sized so the bearing pressure on the concrete stays within limits, and the holding down bolts are designed for any uplift or moment at the base. A nominally pinned base still needs bolts to hold the column in position during erection and to resist any tension. We specify the plate thickness, size, bolt layout and the grout beneath, and coordinate the base with the pad or foundation that receives it so the load path is complete from beam to ground.

Connections, fire and coordination

The top of the column carries the beam it supports, and that connection is designed to BS EN 1993-1-8 for the reaction and any tying force, whether a welded cap plate, a bolted end plate or a cleat. Where several members meet at one node, a beam over and a beam framing in, we detail the connection so the forces resolve cleanly and the steel can actually be bolted up on site. We note bolt grades, weld sizes and any stiffeners the section needs.

Exposed steel columns in a building normally need fire protection to the period required by Approved Document B, by intumescent coating, boarding or encasement, and we flag this so it is allowed for. The finished package gives the column section, base plate detail, connections and fire requirement, ready for fabrication and Building Control. We deliver these designs across the UK, with site visits arranged by region where an existing structure or foundation needs checking before the column is fixed.

Engineering considerations

What we check.

The points our calculations resolve for a project like this.

From the job record

Issued drawings, redacted.

More drawings →
Structural connection detailsRedrawn as vector line work with the entire text layer discarded, so no title block, client name or address exists in the file.
Not sure what you need?Send us your drawings, or just a photograph of the wall. We will tell you what is required and what it costs before you commit to anything.
Process

From enquiry to sign-off.

1

Enquiry

Send drawings or describe the problem. We confirm the scope, the deliverables and a target timescale.

2

Information

We agree the survey, drawings or data we need and any site access required.

3

Engineering

Design, calculation or assessment to the relevant Eurocodes and UK National Annex.

4

Issue

A clear, defensible report or set of calculations, with assumptions and limitations stated.

Questions

Common questions

When do I need a steel column instead of a wall?

When a beam or floor load needs to come down at a point rather than along a line, for example at the end of a beam in an open-plan space where there is no wall to carry it. We design the column to take that load safely to the foundation.

Why does a tall thin post fail before it is squashed?

Because slender compression members buckle. A tall thin column bows out sideways under a load well below the strength of the steel, so buckling, not crushing, governs the design. We size the section against its buckling resistance, which depends on its slenderness and end restraints.

Do you design the base plate and foundation too?

Yes. We size the base plate so the concrete is not overstressed, design the holding down bolts, and coordinate the base with the pad foundation beneath, so the load path runs unbroken from the beam through the column into the ground.

Can a steel post be left exposed?

It can, and hollow sections are often chosen where a post is on show. Exposed structural steel usually still needs fire protection to meet Building Regulations, which can be an intumescent coating that keeps a clean finish. We advise what is required for your situation.

What size steel post do I need?

It depends on the load coming down, the height of the post and how it is restrained top and bottom. We calculate the axial load, allow for any bending from eccentric connections, and size the lightest section that resists buckling. We will not quote a size without those inputs.

Start a project

Tell us what you are building.

£5m PI insuredEurocode basedChecked and signed

Send the drawings or describe the project. We confirm scope, deliverables and a realistic timescale.

Start a project