BS 6399-2 is withdrawn. This is what replaced it.
BS 6399-2, the British Standard for wind loads on buildings, was withdrawn in 2010. It is still cited in specifications, software defaults and even one printing of its own successor's National Annex. The current route is BS EN 1991-1-4 with the UK National Annex, and the numbers do not map one for one.
Is BS 6399-2 still the UK standard for wind loads?
No. BS 6399-2:1997 was withdrawn in 2010. Wind actions in the UK are now determined to BS EN 1991-1-4:2005+A1:2010 with the UK National Annex, NA to BS EN 1991-1-4:2005+A1:2010, supported by PD 6688-1-4:2009. The methods are not interchangeable, and the National Annex's own roof pressure tables replace the Eurocode's. BS 6399-2 is cited correctly only to record what a pre-2010 structure was designed to.
- Withdrawn 2010
- Replaced by BS EN 1991-1-4 with the UK National Annex
- Results do not convert between the two
- Still legitimate for appraising pre-2010 structures
The status of BS 6399-2
BS 6399-2:1997, Loading for buildings, Part 2: Code of practice for wind loads, was withdrawn by BSI in 2010, together with the other conflicting British Standards, when the Eurocodes became the basis of structural design in the UK. Its successor is BS EN 1991-1-4:2005+A1:2010, Eurocode 1 Part 1-4, Wind actions, used with the UK National Annex, NA to BS EN 1991-1-4:2005+A1:2010, and supported by PD 6688-1-4:2009.
BS 6399-1 (dead and imposed loads) and BS 6399-3 (imposed roof loads) were withdrawn at the same time and replaced by BS EN 1991-1-1 and BS EN 1991-1-3. A specification that calls for "loading to BS 6399" is calling for a withdrawn suite, and the engineer who receives it should say so rather than quietly design to something else.
Why it is still cited
Several reasons, none of them good enough. Older textbooks and university notes still teach it. Some software carries it as a selectable or default code. Specification templates copied forward from earlier jobs carry it. Manufacturers' literature written before 2010 quotes its pressure coefficients. And many engineers simply remember its method better than the one that replaced it.
There is one more reason that catches careful people. The 2008 printing of the UK National Annex to BS EN 1991-1-4 made no national choice at clause NA.2.28 and referred the reader to an advisory note recommending the method in BS 6399-2. That printing was superseded by the 2005+A1:2010 edition, in which the same clause makes a national choice and replaces the Eurocode's roof pressure tables with the National Annex's own. An engineer who followed the earlier printing in good faith was pointed back at a withdrawn standard by the successor document itself, which is why the edition of the National Annex has to be named in every wind calculation.
What changes when a design moves to BS EN 1991-1-4
The structure of the calculation is recognisable: a basic wind speed from a map, corrections for the site, a dynamic pressure at a reference height, pressure coefficients for the surfaces, and a factor for the size and dynamic response of the structure. The terms, the maps, the corrections and the coefficients are not the same, and a result produced under one code cannot be read across to the other.
In the UK route the fundamental basic wind velocity is taken from the National Annex map and corrected for altitude, direction and season; the peak velocity pressure is found at the reference height for the site's exposure; and the external pressure coefficients for roofs come from the National Annex's Tables NA.5 to NA.8, because clause NA.2.28 states that the Eurocode's own roof tables should not be used in the UK. Those tables also carry their own interpolation rule: between values of the same sign only, never across a change of sign on one face.
For equipment mounted on roofs, BRE Digest 489 (2014) sits on BS EN 1991-1-4 and is the document to cite for solar arrays and similar installations. An earlier edition of the Digest sat on BS 6399-2 and has been superseded; the year matters here for the same reason the amendment matters on the National Annex.
When citing BS 6399-2 is correct
There is one legitimate use. When appraising a structure designed before 2010, the engineer needs to know what the original designer was working to, and reading the original calculation against BS 6399-2 is how that is done. The appraisal then assesses the structure against the current code and reports the two findings separately. A structure that does not meet the current code's demand is not thereby unsafe, and a report that merges those two statements has misled its reader in one direction or the other.
What is not legitimate is a new design, a strengthening scheme or a loading statement for a new installation prepared to BS 6399-2 in 2026. Building Control will not accept it, a checking engineer will not sign it, and an insurer asked to rely on it after a failure would be entitled to ask why a withdrawn code was used.
How to write the citation
For a new wind calculation in the UK: BS EN 1991-1-4:2005+A1:2010 with NA to BS EN 1991-1-4:2005+A1:2010, and PD 6688-1-4:2009 where it was used. For roof-mounted equipment, add BRE Digest 489 (2014). For an appraisal of a pre-2010 structure: the current documents as above for the assessment, and "originally designed to BS 6399-2:1997 (withdrawn 2010)" for the record of what was found.
Our wind and snow loading assessments and roof loading appraisals are prepared this way, and the Eurocodes hub sets out the wider suite. The page on BS EN 1991-1-4 covers the current wind standard itself.
Documents cited
- BS 6399-2:1997, Loading for buildings, Part 2: Code of practice for wind loads (withdrawn 2010).
- BS EN 1991-1-4:2005+A1:2010, Eurocode 1: Actions on structures, Part 1-4: General actions, Wind actions.
- NA to BS EN 1991-1-4:2005+A1:2010, UK National Annex, incorporating National Amendment No. 1, clause NA.2.28 and Tables NA.5 to NA.8.
- NA to BS EN 1991-1-4:2005, 2008 printing, clause NA.2.28 and its advisory note.
- PD 6688-1-4:2009, Background information to the National Annex to BS EN 1991-1-4 and additional guidance.
- BRE Digest 489 (2014), Wind loads on roof-based photovoltaic systems.
Common questions
Is BS 6399-2 still a valid standard?
No. It was withdrawn by BSI in 2010 and replaced by BS EN 1991-1-4 with the UK National Annex. It remains useful only for understanding what a pre-2010 structure was designed to.
Can wind loads from BS 6399-2 be converted to BS EN 1991-1-4?
Not reliably. The maps, the site corrections, the reference heights and the pressure coefficients differ, and the UK National Annex replaces the Eurocode's own roof tables with its own. A structure has to be re-assessed under the current route, not converted.
Why did a National Annex recommend a withdrawn standard?
The 2008 printing of the National Annex to BS EN 1991-1-4 predates the withdrawal and made no national choice at clause NA.2.28, pointing instead to an advisory note that recommended the BS 6399-2 method. The 2005+A1:2010 edition replaced that with the National Annex's own roof pressure tables. Citing the edition is what tells a reader which was followed.
What should a specification say instead of "wind loading to BS 6399"?
Wind actions to BS EN 1991-1-4:2005+A1:2010 with the UK National Annex (NA to BS EN 1991-1-4:2005+A1:2010), and PD 6688-1-4:2009 where applicable. For roof-mounted plant or solar arrays, BRE Digest 489 (2014).
Related services and resources.





Tell us what you are building.
Send the drawings or describe the project. We confirm scope, deliverables and a realistic timescale.
Start a project