What does BS EN 1991-1-4 cover?
BS EN 1991-1-4 is the Eurocode for wind actions on buildings and civil engineering works. In the UK it is used as BS EN 1991-1-4:2005+A1:2010 with the UK National Annex, which supplies the UK wind map, the site corrections and, for roofs, its own tables of pressure coefficients in place of the Eurocode's. PD 6688-1-4:2009 gives the supporting UK guidance. It replaced BS 6399-2 in 2010.
- Current edition 2005+A1:2010, with NA 2005+A1:2010
- UK roof coefficients from Tables NA.5 to NA.8, not the Eurocode's
- PD 6688-1-4:2009 for UK complementary guidance
- BRE Digest 489 (2014) for roof-mounted equipment
Scope and status
BS EN 1991-1-4 is Eurocode 1, Part 1-4: General actions, Wind actions. The current UK edition is BS EN 1991-1-4:2005+A1:2010, used with NA to BS EN 1991-1-4:2005+A1:2010, which incorporates National Amendment No. 1. It gives the wind actions for the structural design of buildings and civil engineering works, their components and attachments, and it replaced BS 6399-2, which was withdrawn in 2010.
Alongside the National Annex, PD 6688-1-4:2009 provides what its own scope calls non-contradictory complementary information for use in the UK with BS EN 1991-1-4 and its National Annex. The National Annex cites it, and for forms the Eurocode does not cover well it is frequently the document that settles the question.
How a UK wind calculation runs
The route is the same on every job and is set out in the package in this order. A fundamental basic wind velocity is taken from the National Annex map and corrected for the site: altitude, the direction being considered and, where the structure is temporary or seasonal, the season. From that a peak velocity pressure is found at the reference height, reflecting the site's exposure and distance from the sea and from the edge of town.
External and internal pressure coefficients are then applied to each surface. For walls the Eurocode's coefficients are used with the National Annex's modifications; for roofs the National Annex supplies its own tables, discussed below. A structural factor accounts for the size of the loaded area and the dynamic response of the structure, and for most low-rise buildings it is close to unity. The resulting pressures are combined into the forces the structure, its cladding and its fixings are designed for.
Everything above is stated in the package with the clause, table or figure it came from, so a checker can follow the same route in the same documents. That is what makes a wind calculation reproducible rather than merely plausible.
The National Annex tables that replace the Eurocode's
Clause NA.2.28 of the National Annex states that the Eurocode's Tables 7.2, 7.3a), 7.3b), 7.4a), 7.4b) and 7.5, the external pressure coefficients for flat, monopitch, duopitch and hipped roofs, should not be used in the UK. The National Annex's Tables NA.5 (flat), NA.6a) and NA.6b) (monopitch), NA.7a) and NA.7b) (duopitch) and NA.8 (hipped) are used instead. The Eurocode's zone figures, which define where zones F to J fall on the roof, are retained; only the values change.
The UK tables carry their own rules. Interpolation is between values of the same sign only; a positive and a negative coefficient on the same face are never averaged. The hipped roof table serves both wind directions in a single table, unlike the duopitch pair. The values differ from the Eurocode's own at several pitches, so a roof checked with the European tables in the UK has used the wrong numbers, not merely a slightly different convention.
For curved roofs and domes the Eurocode's Figure 7.11, in clause 7.2.8, remains the source of the external pressure coefficients, with zones A, B and C defined by the rise to span ratio and the windward zone interpolated for low wall heights. We applied it to a pair of curved industrial vaults in 2026 and it is the kind of case where the package has to show its working, because the figure, not a table, gives the answer.
Common misapplications
Using the Eurocode's roof tables rather than the National Annex's, which clause NA.2.28 rules out in the UK. Following the 2008 printing of the National Annex, which made no national choice at NA.2.28 and pointed to an advisory note recommending the method in the withdrawn BS 6399-2. Mixing signs when interpolating within the UK roof tables. Taking a local coefficient where an overall one applies, or the reverse, so that cladding fixings are under-designed or the main structure is over-designed.
Ignoring altitude and the site's orography on an exposed or elevated site, which can move the peak velocity pressure materially. Treating a container, a market stall or a temporary stage as if it were a permanent building, when a seasonal factor and a check on overturning and sliding are what the structure actually needs. And, most often, citing "BS EN 1991-1-4" without the amendment or the National Annex, so that nobody reading the package can tell which edition's rules were followed.
For equipment on roofs, including solar arrays, BRE Digest 489 (2014) sits on this standard and is the document to cite. The withdrawn standard it replaced is covered on the BS 6399-2 page, and the wider suite on the Eurocodes hub.
Where it is applied
Wind governs more outcomes than any other action on the structures we see most: industrial and commercial roofs taking new plant or a change in loading, cladding and its fixings, canopies, signage and totems, temporary and event structures, rooftop plant, and lightweight or tall structures of every kind. It is also the action most often done wrong in a package we are asked to check.
Our wind and snow loading assessments are prepared to BS EN 1991-1-4:2005+A1:2010 with the UK National Annex and PD 6688-1-4:2009, state every clause and table applied, and are checked and signed before issue.
Documents cited
- BS EN 1991-1-4:2005+A1:2010, Eurocode 1: Actions on structures, Part 1-4: General actions, Wind actions, including clause 7.2.8 and Figure 7.11.
- NA to BS EN 1991-1-4:2005+A1:2010, UK National Annex, incorporating National Amendment No. 1, clause NA.2.28 and Tables NA.5, NA.6a), NA.6b), NA.7a), NA.7b) and NA.8.
- NA to BS EN 1991-1-4:2005, 2008 printing, clause NA.2.28 and its advisory note.
- PD 6688-1-4:2009, Background information to the National Annex to BS EN 1991-1-4 and additional guidance, clause 1 Scope.
- BRE Digest 489 (2014), Wind loads on roof-based photovoltaic systems.
- BS 6399-2:1997 (withdrawn 2010), for the record of what it replaced.
Common questions
What is the current UK wind loading standard?
BS EN 1991-1-4:2005+A1:2010, Eurocode 1 Part 1-4, Wind actions, used with the UK National Annex, NA to BS EN 1991-1-4:2005+A1:2010, and supported by PD 6688-1-4:2009. It replaced BS 6399-2, withdrawn in 2010.
Does the UK use the Eurocode's own roof pressure coefficients?
No. Clause NA.2.28 of the UK National Annex states that the Eurocode's roof tables should not be used in the UK and replaces them with Tables NA.5 to NA.8. The Eurocode's zone figures are kept; the values come from the National Annex.
What is PD 6688-1-4?
A BSI Published Document, PD 6688-1-4:2009, giving background information to the National Annex to BS EN 1991-1-4 and additional guidance. Its scope describes it as non-contradictory complementary information for use in the UK with the standard and its National Annex.
Which document covers wind on solar panels?
BRE Digest 489 (2014), Wind loads on roof-based photovoltaic systems, which sits on BS EN 1991-1-4. The earlier edition sat on BS 6399-2 and is superseded.