BS EN 1992-1-1: design of concrete structures and the UK National Annex
Eurocode 2 replaced BS 8110 for concrete design. The UK National Annex adopts most of the Eurocode's recommended parameters, departs on the ones that matter for strength and durability, and sends cover to a British Standard the Eurocode does not mention.
What is BS EN 1992-1-1?
BS EN 1992-1-1 is Eurocode 2, the standard for the design of concrete structures, used in the UK with its National Annex. The National Annex adopts the recommended material factors, sets alpha cc at 0.85 for flexure and axial compression, takes cover from BS 8500-1 rather than the Eurocode's tables, and replaces the crack width table with its own Table NA.4. It replaced BS 8110, withdrawn in 2010.
- Material factors as recommended at ULS, 1.0 at SLS
- alpha cc 0.85 in flexure and axial compression
- Cover from BS 8500-1, deviation 10 mm
- Crack widths from Table NA.4
Scope and status
BS EN 1992-1-1, Eurocode 2 Part 1-1: Design of concrete structures, General rules and rules for buildings, is used in the UK with its National Annex and replaced BS 8110, withdrawn in 2010. Fire design is in Part 1-2, bridges in Part 2 and liquid-retaining structures in Part 3. For an existing concrete frame designed before 2010 the old code is read to establish the original basis; the assessment is to Eurocode 2.
The UK National Annex to BS EN 1992-1-1:2004 takes a different approach from the masonry and steel annexes. Its Table NA.1 adopts the Eurocode's recommended value for most Nationally Determined Parameters and departs on a handful, and the departures are the ones that decide strength and durability. A calculation that applies the recommended values throughout has got most of it right and the important parts wrong.
Material factors and alpha cc
For the material partial factors at the ultimate limit state, the National Annex at clause 2.4.2.4(1) directs the designer to the Eurocode's recommended values in Table 2.1N for concrete and reinforcing steel. At the serviceability limit state, clause 2.4.2.4(2), both are 1.0. The partial factor for shrinkage is the recommended 1.0, and the National Annex reduces the prestress factors from the recommended values, to 0.9 where prestress is favourable and 1.1 where it is unfavourable.
The departure that matters most for everyday design is the coefficient alpha cc, which allows for long-term effects and the way load is applied on the compressive strength. The Eurocode recommends 1.0. The UK National Annex, at clause 3.1.6(1)P, sets it at 0.85 for compression in flexure and axial loading and 1.0 for other phenomena, and allows 0.85 to be taken conservatively throughout. A beam or column designed with alpha cc at 1.0 in the UK has overstated its concrete compressive capacity by about 18 per cent. The tensile coefficient alpha ct stays at the recommended 1.0, and the upper limit on the characteristic yield strength of reinforcement is the recommended 600 MPa.
Cover and durability
This is where the UK route leaves the Eurocode's text altogether. For the minimum cover for durability, clause 4.4.1.2(5), the Eurocode offers Table 4.3N for structural classification and Tables 4.4N and 4.5N for values. The UK National Annex does not use them: it directs the designer to BS 8500-1 and its tables for concrete quality and cover by exposure class. A UK concrete specification therefore cites BS 8500 alongside Eurocode 2, and a cover taken from the Eurocode's own tables is not the UK requirement.
The allowance for deviation, clause 4.4.1.3(1)P, is the recommended 10 mm, reduced under controlled conditions by the Eurocode's own expressions. Nominal cover is the minimum plus that allowance, which is the figure that goes on the drawing and the one a site should be measuring against. On an existing structure the cover actually present is measured, not read from a drawing, because the difference between the two is the usual reason a slab or beam has carbonated and spalled.
Serviceability
Crack width limits are a national decision. Clause 7.3.1(5) of the Eurocode gives Table 7.1N; the UK National Annex replaces it with its own Table NA.4, which sets the limits by exposure class and by whether the member is reinforced or prestressed. The effective tensile strength used in the crack calculation follows the recommended route. Deflection limits follow the Eurocode's span to depth approach, with the usual UK practice of checking the appearance limit against the span over 250.
The distance between movement joints that lets the effects of temperature and shrinkage be neglected, clause 2.3.3(3), is the recommended 30 m. Beyond it, or where a structure is restrained, those effects are designed for rather than ignored, which is a point that recurs on long ground-bearing slabs and on the podium decks of residential schemes.
Where it is applied
On new work the package names the parts applied, the National Annex, BS 8500 for the concrete specification and cover, and the exposure classes used, so a checker can reproduce the route. On existing buildings the assessment establishes what is there by investigation, including cover and reinforcement by survey and, where justified, by opening up, and reports the margin against current code separately from whether the structure is safe in its current use. For precast planks of a different material altogether, see RAAC inspection and remediation; RAAC is not designed or assessed as ordinary concrete.
Combinations are to BS EN 1990, loads to BS EN 1991-1-1, and the wider suite is set out on the Eurocodes hub. Our design and calculation packages and independent checks are prepared on this route.
Documents cited
- BS EN 1992-1-1:2004, Eurocode 2: Design of concrete structures, Part 1-1: General rules and rules for buildings, Table 2.1N, clauses 2.3.3(3), 3.1.6, 4.4.1.2, 4.4.1.3 and 7.3.1.
- NA to BS EN 1992-1-1:2004, UK National Annex to Eurocode 2, Part 1-1, Table NA.1 (decisions at 2.3.3(3), 2.4.2.1(1), 2.4.2.2(1) to (3), 2.4.2.4(1) and (2), 3.1.6(1)P and (2)P, 3.2.2(3)P, 4.4.1.2(5), 4.4.1.3(1)P and (3), 7.3.1(5)) and Table NA.4.
- BS 8500-1, Concrete, Complementary British Standard to BS EN 206, Part 1: Method of specifying and guidance for the specifier, as cited by the National Annex for concrete quality and cover.
- BS 8110 (withdrawn 2010), for the record of what it replaced.
Common questions
Does the UK use the Eurocode's recommended partial factors for concrete and steel?
At the ultimate limit state, yes: the UK National Annex at clause 2.4.2.4(1) adopts the recommended values of Table 2.1N. At the serviceability limit state both are 1.0.
What is alpha cc in the UK?
0.85 for compression in flexure and axial loading and 1.0 for other phenomena, under clause 3.1.6(1)P of the UK National Annex, which also allows 0.85 to be used conservatively throughout. The Eurocode's recommended value is 1.0.
Where does UK concrete cover come from?
From BS 8500-1, which the UK National Annex cites at clause 4.4.1.2(5) in place of the Eurocode's Tables 4.3N, 4.4N and 4.5N. The deviation allowance is the recommended 10 mm.
Which crack width limits apply in the UK?
Those in Table NA.4 of the UK National Annex, which replaces the Eurocode's Table 7.1N under clause 7.3.1(5).